Reliability and versatility of the Wise pattern, medial pedicle for breast reduction in South Africa

LATEST ARTICLES
SEARCH INDEX
SUGGEST ARTICLE
THE OSI COLLECTIONS
ABOUT THE OSI

OSI STATISTICS

Total abstracts indexed:
534
Audio abstracts:
101
Open access articles:
474
Pending review:
115
Annotations added:
2
Countries represented:
91
No. of contributors:
10
Bookmarks made:
12
Specialities covered:
19

Reliability and versatility of the Wise pattern, medial pedicle for breast reduction in South Africa


JournalSurgery Open Science
Publication date – Jan – 2020
Authors – Marietha Nel, Elias Ndobe, Aylwyn Mannell, Letlhogonolo Brian Andrew Monaisa
KeywordsMammary hyperplasia, Medial pedicle, Minimally undermined, Reliability, Versatility, Wise pattern
Open access – Yes
SpecialityGeneral surgery, Plastic surgery
World region Southern Africa
Country: South Africa
Language – English
Submitted to the One Surgery Index on May 12, 2020 at 5:39 am
Abstract:

Background
Breast hypertrophy is a condition of abnormal enlargement of the breast which may continue until each breast weighs more than 1.5 kg (macromastia) or even more than 2 kg (gigantomastia). Supporting such heavy weights leads to cervical and upper thoracic back pain, costochondritis, and fungal infections in the mammary folds, making reduction mammoplasty essential. However, there is a lack of consensus among plastic surgeons as to the best technique. This study reports the results of reduction mammoplasties in South African women using the Wise pattern, minimally undermined with a medial pedicle.

Methods
A retrospective record review of the reduction mammoplasties was conducted over a 1-year period. Patient records were assessed for early complications related to vascular reliability.

Results
One hundred and fourteen Wise pattern minimally undermined, medial pedicle techniques were performed on 57 consecutive patients in the 1-year period at the NetCare Rand Clinic in Berea, Johannesburg, South Africa (EN). The patients’ sternal notch to nipple distances ranged from 28 to 52 cm. The volume of breast reduction ranged from 345 g to 3300 g per breast. The overall complication rate was 9.7%, consisting of fat necrosis (3.5%), infection (1.7%), dehiscence (3.5%), and nipple epidermolysis (0.9%).

Conclusion
The minimally undermined Wise pattern medial pedicle breast reduction technique proved to be a reliable technique for breast reduction in the South African population. Safety in pedicle breast reduction with sternal notch to nipple distances of up to 50 cm, as well as reliability and versatility in a wide range of breast sizes, was demonstrated.

OSI Number – 20361